  • Space Heat Pump

  • Geothermal (Ground Source Heat Pump)
  • - Open systems
    - Heating COPh ≥ 3.6 with 10°C entering water
    - Cooling COPc ≥ 4.75 with 15°C entering water
    - Closed loop systems
    - Heating COPh ≥ 3.1 with 0°C entering water
    - Cooling COPc ≥ 3.93 with 25°C entering water
  • Air Source Heat Pump
  • The newly installed system must meet the following criteria:
    - Compressor must be of variable capacity with three or more distinct operating speeds, or continuously variable speed
    - Minimum total rated heating capacity at 8.3 °C of 3.52 kW (12,000 BTU/h)
    - HSPF (AHRI Climate Region Zone IV) ≥ 10
    - Central system or minimum three indoor heads for ductless
    - COP ≥ 1.8 at -15 °C (5 °F) (at maximum capacity operation);
    - Capacity maintenance (Max -15 °C (5 °F)/Rated 8.3 °C (47 °F)) ≥ 70%
  • The newly installed system must meet the following criteria:
    - Minimum total rated heating capacity at 8.3 °C of 3.52 kW (12,000 Btu/h)
    - HSPF (AHRI Climate Region Zone IV) ≥ 10
    - Central ducted system or minimum three indoor heads for ductless units
  • The newly installed system must meet the following criteria:
    - Minimum total rated heating capacity at 8.3 °C of 3.52 kW (12,000 Btu/h)
    - HSPF (AHRI Climate Region Zone IV) ≥ 10
    - Two indoor heads ductless unit
    In addition, the cold climate air source heat pump (ccASHP) system must meet the following criteria:
    - Compressor must be of variable capacity with three or more distinct operating speeds, or continuously variable speed
    - COP ≥ 1.8 at -15 °C (5 °F) (at maximum capacity operation);
    - Capacity maintenance (Max -15 °C (5 °F)/Rated 8.3 °C (47 °F)) ≥ 70%
  • Windows and Doors

  • Exterior Wall Insulation

  • Water Heating

  • Replace domestic water heater with an ENERGY STAR® certified domestic hot water heat pump. Energy efficiency performance and installation:
    - Capacity ≤ 55 gal
    - EF ≥ 2.00 with FHR ≥ 50 gallons per hour or UEF ≥ 2.00 FHR ≥ 45 gallons per hour
    - Capacity > 55 gal
    -EF ≥ 2.20 FHR ≥ 50 gallons per hour or UEF ≥ 2.20 FHR ≥ 45 gallons per hour
  • Renewable Energy Systems

  • 1000/ kW
  • Resiliency Measures

  • Attic

  • Attic Insulation
  • Cathedral/Flat Roof Insulation
  • Basement

  • Basement Insulation
  • Basement Slab Insulation
  • Basement Header Insulation
  • Crawlspace (including header area)
  • Exposed Floor Insulation

  • Air Sealing

  • $0.00
  • Total Rebate

    Maximum $5,600